AF610 Airflow Capture Hood (Balometer), 85 to 3,400 m³/h

AF610 airflow capture hood balometer with 610 x 610 mm hood and display base

AF610 Airflow Capture Hood (Balometer), 85 to 3,400 m³/h

R65,000.00 Excl. VAT

In stock

R65,000.00 Excl. VAT

The AF610 balometer (airflow capture hood) reads air volume straight off supply diffusers, return grilles and exhaust outlets from 85 to 3,400 m³/h, with air temperature shown at the same time. A multi-point averaging grid, 610 x 610 mm hood and 100-reading memory make it a fast, single-person tool for HVAC testing, adjusting and balancing. 1 to 3 Weeks lead time.

Availability: Available on backorder SKU: AF610 Categories: ,
View cart

Description

Read Diffuser Airflow Directly, No Traverse, No Calculations

Hold the AF610 over a ceiling diffuser, grille or exhaust outlet and the display shows the total air volume in m³/h or CFM, together with air temperature. The hood captures all the air leaving the outlet and a multi-point grid averages it across the full face, so balancing a room takes minutes instead of a full anemometer traverse.

Airflow range85 to 3,400 m³/h
Accuracy (supply)±3% + 12 m³/h
Temperature−10 to 80°C
Hood size610 x 610 mm
Memory100 readings + RS232
Power3 x AA, 10 h+

Balometer, flow hood, capture hood: what is it?

A balometer is an instrument that measures the total volume of air flowing through a supply diffuser, return grille or exhaust outlet. The same instrument goes by several names in the HVAC trade:

  • Balometer: the common trade name, from its main use in air balancing
  • Flow hood: short for airflow hood or air volume hood
  • Air capture hood: the fabric hood captures all the air from the outlet and channels it over the sensing grid
  • Air balancing hood: used by TAB (testing, adjusting and balancing) contractors to set each outlet to its design airflow

Unlike a vane or hot-wire anemometer, which measures air velocity at single points and needs the outlet area to calculate volume, a balometer gives the air volume directly in m³/h or CFM.

Applications

  • HVAC testing, adjusting and balancing (TAB): set each diffuser to its design air volume
  • Commissioning: verify ventilation systems in new and refurbished buildings
  • Supply, return and exhaust grilles: measure both intake and exhaust airflow
  • Fresh air and extract checks: offices, hospitals, cleanrooms, laboratories and other commercial buildings
  • Maintenance and troubleshooting: find blocked, unbalanced or under-performing outlets

Features

  • Direct air volume read-out in m³/h or CFM, with no area or K-factor calculation
  • Supply and exhaust measurement with one instrument
  • Airflow and temperature displayed together
  • Cross-pattern multi-point averaging grid for an even reading across the whole hood face
  • Lightweight nylon fabric hood on a rigid base with built-in handles
  • Adjustable-angle display for easy reading when working overhead
  • Simple four-key menu
  • Stores 100 readings with RS232 data output
  • Interchangeable hood sizes available for different outlet sizes

How it works

  1. Position: lift the hood over the diffuser or grille so the foam rim seals against the ceiling or wall.
  2. Capture: all air from the outlet passes through the hood and over the multi-point sensing grid in the base.
  3. Read: the display shows the averaged air volume and air temperature; save the reading to memory.
Good to know: allow a 15-minute warm-up before measuring. Choose a hood size that covers the full outlet; ask us about other hood sizes when ordering.

Specifications

  • Model: AF610
  • Airflow range: 85 to 3,400 m³/h (50 to 2,000 CFM)
  • Accuracy, supply (intake): ±(3% of reading + 12 m³/h) / ±(3% of reading + 7 CFM)
  • Accuracy, exhaust: ±(4% of reading + 12 m³/h) / ±(4% of reading + 7 CFM)
  • Airflow resolution: 0.1 m³/h
  • Temperature range: −10 to 80°C (14 to 176°F)
  • Temperature accuracy: ±(0.5% of reading + 0.5°C)
  • Temperature resolution: 0.1°C / 0.1°F
  • Display: 128 x 64 dot-matrix LCD, adjustable viewing angle
  • Controls: four-key menu
  • Data memory: 100 records
  • Data output: RS232C
  • Power supply: 3 x 1.5 V AA batteries
  • Battery life: minimum 10 hours
  • Warm-up time: 15 minutes
  • Standard hood: 610 x 610 mm nylon fabric (interchangeable hoods available)
  • Weight: approx. 4 kg with 610 x 610 mm hood
  • Protection class: IP65 (as stated by manufacturer)
  • Compliance: RoHS
  • Warranty: 12 months

Standard configuration

  • Measuring instrument (display unit)
  • Base with multi-point averaging grid and handles
  • 610 x 610 mm nylon capture hood with support frame

Need a different hood size or a quote for several units? Call +27 21 911 5835 or email sales@ecotao.co.za.

Additional information

Weight4 kg
Dimensions61 × 61 cm