CX105 Conductivity Transmitter Loop-Powered 4-20mA
R20,670.00 Excl. VAT
Our CX105 is an isolated output 4-20mA industrial transmitter for reading contacting Conductivity sensors, as well as TDS and Resistivity. Easily power the unit with an available two-wire power supply loop. Ideal for connecting to a PLC for advanced control systems. Versatile mounting options for wall or panel mount. With a dual display LCD, monitoring both the measuring value and the temperature is simple. The CX105 is CE certified. Lead time is 4 weeks.
- Description
- Additional information
Description
CX105 Conductivity Transmitter Loop-Powered 4-20mA
Our CX105 conductivity transmitter is an isolated output 4-20mA industrial transmitter for reading contacting conductivity sensors. The CX105 transmitter also measures Resistivity and TDS. Easily power the unit with an available two-wire power supply loop. This transmitter is ideal for connecting to a PLC for advanced control systems. The CX105 has versatile mounting options for wall or panel mount. With a dual-display LCD, monitoring both the measured value and the temperature is simple.
NOTE: The transmitter is compatible only with sensors with tinned leads and Pt1000Ω RTD temperature compensation.
Features
- The dual display shows the measuring value and temperature
- Large LCD screen for easy reading
- Compatible with a wide variety of contacting conductivity, resistivity, and TDS sensors
- Isolated 4-20 mA analog output
- Automatic temperature compensation
- Flexible mounting options
- One-year limited warranty
- CE certified – compliant with European Community Standards
Specifications
- Display: LCD: 128*65 dot matrix, figure or alphabet: 12×8, 28×15, 32×18, etc.,
- Display Update rate: 1 second
- Display Contrast: User selected, 5 levels
Measurement:
- Conductivity: 0.05 to 500,000 μS/cm
- Resistivity: 1KΩ•cm to 18.3MΩ•cm
- TDS: 0.023 to 200,000 ppm
- Accuracy: ± 0.5% of reading
- Repeatability: ± 0.05% of span
- Temperature Drift: Zero and Span: ± 0.02% of span per℃
- These performance specifications are typical at 25°C
Electrical:
- Power: 19 -48VDC, regulated, 30mA maximum
Current Output:
- Isolated 4-20 mA output with 0.004 mA (12-bit) resolution
- Update Rate: 1 second
- Maximum Loop Impedance: 250Ω@24V; 600Ω@31V; 1500Ω@48V
Memory:
- Non-volatile: All user settings are retained indefinitely without battery backup
Open-Collector Output:
- Isolated, 40 VDC max. pull-up voltage
- The OC output can be configured to be one of three modes below:
- High mode, Low mode, Proportional pulses
Ambient Conditions:
- Operation: -10 °C to 70 °C (14 °F to 158 °F); 0-95% relative humidity, non-condensing
- Transport/storage: -15°C to 80°C(5°F to 176°F); 0-95% relative humidity, non-condensing
Standards and Approvals
- CE: Certified Compliant to European Community Standards.
Additional information
| Weight | 1 kg |
|---|---|
| Dimensions | 20 × 20 × 15 cm |