9-19 High Pressure Centrifugal Blowers, 3kW to 30kW

9-19 High Pressure Centrifugal Blowers, 3kW to 30kW

Price range: R16,500.00 through R63,500.00 Excl. VAT

In stock

Price range: R16,500.00 through R63,500.00 Excl. VAT

Direct driven 9-19 A type high pressure centrifugal blowers for forced ventilation and pneumatic conveying, in seven models from 3kW to 30kW at 380V and 2900rpm. They deliver 824 to 6,978m³/h at total pressures from 3,253 to 9,265Pa; choose your model from the Select model dropdown below to see its price. 1-3 Weeks lead time.

SKU: N/A Categories: ,
Clear
View cart

Description

9-19 High Pressure Centrifugal Blower, 3kW to 30kW

The 9-19 A type is a single inlet, direct driven high pressure centrifugal fan for forced ventilation and pneumatic conveying where a standard fan cannot build enough pressure. Seven models cover air flows from 824 to 6,978m³/h and total pressures from 3,253 to 9,265Pa, all running at 2900rpm on a 380V motor.

Important: choose your model at the top of the page

This listing covers 7 different blowers. Use the Select model dropdown next to the product photo to pick your model, see its price and add it to your cart. Not sure which one you need? Use the model guide below.

Go to Select model ↑

Air flow824 to 6,978m³/h
Total pressure3,253 to 9,265Pa
Motor power3kW to 30kW
Speed2900rpm
Voltage380V
DriveDirect (A type)

How to choose your model

  1. Work out the air flow you need in m³/h and the total pressure (system resistance) in Pa.
  2. Find the row in the table below where both your air flow and your pressure fall inside the ranges.
  3. If two models fit, the larger motor gives you more air flow headroom. If you are not sure of the pipeline resistance, choose the bigger motor or fit an adjustment damper so the motor is not overloaded.
ModelFan size (impeller)MotorMotor frameAir flow (m³/h)Total pressure (Pa)
9-19-4.0A-2-3KW4# (400mm)3kWY100L-2824 to 1,7043,253 to 3,665
9-19-4.5A-2-5.5KW4.5# (450mm)5.5kWY132S1-21,174 to 2,5044,112 to 4,684
9-19-5.0A-2-7.5KW5# (500mm)7.5kWY132S2-21,610 to 3,1665,323 to 5,768
9-19-5.0A-2-11KW5# (500mm)11kWY160M1-21,610 to 3,4885,080 to 5,768
9-19-5.6A-2-11KW5.6# (560mm)11kWY160M1-22,262 to 3,1677,182 to 7,273
9-19-5.6A-2-18.5KW5.6# (560mm)18.5kWY160L-22,262 to 4,9016,400 to 7,273
9-19-6.3A-2-30KW6.3# (630mm)30kWY200L1-23,220 to 6,9788,148 to 9,265

Pressure is highest at low air flow and drops as the air flow increases.

Found your model? Pick the same model name in the Select model dropdown at the top of the page to see the price and order.

Performance curves

9-19 high pressure centrifugal blower performance curves, air flow versus total pressure at 2900rpm for sizes 4# to 6.3#
Air flow against total pressure for each fan size at 2900rpm.
Full performance data (7 duty points per fan size)
Fan sizePointAir flow (m³/h)Total pressure (Pa)Motor needed
4#18243,5842.2kW*
4#29703,6652.2kW*
4#31,1163,6472.2kW*
4#41,2643,5972.2kW*
4#51,4103,5073kW
4#61,5583,3843kW
4#71,7043,2533kW
4.5#11,1744,6034kW*
4.5#21,3974,6844kW*
4.5#31,6164,6724kW*
4.5#41,8394,5804kW*
4.5#52,0624,4474kW*
4.5#62,2814,2975.5kW
4.5#72,5044,1125.5kW
5#11,6105,6977.5kW
5#21,9325,7687.5kW
5#32,2545,7407.5kW
5#42,5765,6397.5kW
5#52,8445,5177.5kW
5#63,1665,3237.5kW
5#73,4885,08011kW
5.6#12,2627,18211kW
5.6#22,7147,27311kW
5.6#33,1677,23611kW
5.6#43,6197,10918.5kW
5.6#53,9966,95418.5kW
5.6#64,4486,70918.5kW
5.6#74,9016,40018.5kW
6.3#13,2209,14918.5kW*
6.3#23,8659,26518.5kW*
6.3#34,5099,21918.5kW*
6.3#45,1539,05518.5kW*
6.3#55,6908,85730kW
6.3#66,3348,54330kW
6.3#76,9788,14830kW

* Smaller motor option for this duty point, not stocked. The motor of the model you buy covers all points of its fan size up to its rated air flow.

Applications

High pressure forced ventilation for forging and smithing, glass, ceramics, electronics, electroplating and battery manufacturing, and pneumatic conveying of grain, animal feed and mineral powders.

Suitable gas: air, or gas that is not flammable or explosive, not harmful to people and not corrosive to copper. Dust content must not exceed 150mg/m³ and the gas temperature must not exceed 80°C.

Features

  • High pressure output, up to 9,265Pa total pressure
  • Single inlet, forward type fan in five sizes: 4#, 4.5#, 5#, 5.6# and 6.3#
  • A type direct drive: high transmission efficiency, simple drive and easy maintenance
  • Impeller statically and dynamically balanced for steady running and long life
  • Right hand or left hand rotation available
  • Outlet angles 0°, 90° and 180° as standard; 45°, 135° and 225° on special order
  • Suitable for both suction and exhaust duty

Rotation and outlet position

Viewed from the motor side, a fan whose impeller turns clockwise is right hand rotation and anticlockwise is left hand rotation. The outlet angle is set by the fan housing. Please state the rotation and outlet angle you need when ordering.

Specifications

  • Type: 9-19 A type high pressure centrifugal fan, single inlet
  • Drive: Direct drive (motor shaft carries the impeller)
  • Fan sizes: 4#, 4.5#, 5#, 5.6#, 6.3# (400 to 630mm impeller)
  • Speed: 2900rpm
  • Voltage: 380V
  • Motor power: 3, 5.5, 7.5, 11, 18.5 or 30kW
  • Air flow: 824 to 6,978m³/h
  • Total pressure: 3,253 to 9,265Pa
  • Maximum gas temperature: 80°C
  • Maximum dust content: 150mg/m³
  • Dimensions: see the Dimensions tab

Installation

Correct

  • Bolt the fan support frame to a level concrete floor
  • Or bolt the motor to a concrete plinth
  • Or mount the motor on a rigid, braced bracket
Wrong

  • Motor mounted on the fan housing
  • Motor mounted on the inlet flange
  • Motor mounted on the outlet flange

Before start-up and maintenance

  • Check the ductwork is clear of anything that could block the fan
  • On the first test run, confirm the wiring is correct, there is no abnormal noise, the running current is within the motor rating and the fan turns in the marked direction
  • Do not run a full-open test for longer than 3 minutes
  • Do not switch the fan on and off too often, as this can burn out the motor
  • Keep the motor cooling fan and cooling fins clear so the motor does not overheat
  • Inspect fan parts regularly and clean dirt or oil off the impeller to keep it balanced
  • If there is abnormal noise or vibration, stop the fan at once and fix the fault before restarting

Troubleshooting

ProblemPossible causes
Not enough air flowAir leaks in the ductwork; actual system resistance higher than calculated; wrong rotation direction
VibrationImpeller out of balance; base not secure; parts rubbing (often with abnormal noise); motor bearing damaged
Motor overloadAir flow above rating; gas density too high; supply voltage too low
Abnormal noiseMotor bearing damaged; rotating parts damaged; duct resonance; fan vibrating
Fan will not startPoor power supply connection

1-3 Weeks lead time. Contact us on +27 21 911 5835 or sales@ecotao.co.za for help selecting the right model.

Additional information

WeightN/A
DimensionsN/A
Select model

9-19-4.0A-2-3KW, 9-19-4.5A-2-5.5KW, 9-19-5.0A-2-11KW, 9-19-5.0A-2-7.5KW, 9-19-5.6A-2-11KW, 9-19-5.6A-2-18.5KW, 9-19-6.3A-2-30KW

Dimension drawing

9-19 high pressure centrifugal blower dimension drawing showing front and side views with inlet and outlet flanges
Front view (left) and side view (right). All dimensions in mm. Use the letters to read the tables below.

Overall and foundation dimensions (mm)

ModelEFGKMNLabcdeBase bolts
9-19-4.0A-2-3KW669262584286722430470200350503003854 x Ø15
9-19-4.5A-2-5.5KW749295657322798470570200390503004404 x Ø15
9-19-5.0A-2-7.5KW829328730358864500580340450504404954 x Ø15
9-19-5.0A-2-11KW829328730358892528675340450504404954 x Ø15
9-19-5.6A-2-11KW925367817401958550690350480504505254 x Ø15
9-19-5.6A-2-18.5KW925367817401958550735350480504505254 x Ø15
9-19-6.3A-2-30KW10404139214511121660890450570605706204 x Ø20

M = overall height, G = overall width, L = overall depth. a, b, c, d and e give the base frame bolt positions.

Outlet flange, rectangular (mm)

Fan sizeA1A2A3B1B2B3XYBolt holes
4#128160182921261484314 x Ø7
4.5#1441761981041351604314 x Ø7
5#1601922141151501714314 x Ø7
5.6#1792122331291621854314 x Ø7
6.3#2032362581461802044314 x Ø7

A1 x B1 = outlet opening. A2 x B2 = bolt hole pitch, with X equal spaces along A2 and Y along B2.

Inlet flange, round (mm)

Fan sizeD1D2D3Bolt holes
4#Ø180Ø210Ø2344 x Ø7
4.5#Ø200Ø230Ø2544 x Ø7
5#Ø224Ø260Ø2854 x Ø7
5.6#Ø250Ø285Ø3128 x Ø10
6.3#Ø280Ø325Ø3608 x Ø10

D1 = inlet diameter, D2 = bolt hole circle, D3 = flange outside diameter.

Original dimension tables
9-19 high pressure centrifugal blower flange and drive side dimension tables for sizes 4# to 6.3#